You Received a Broward County Fire Violation for No Emergency Action Plan. Here Is What to Do Next.
The BSO Fire Prevention Bureau inspection report is sitting on your desk. Somewhere near the bottom of the violation list: "Failure to provide a written Emergency Action Plan reviewed by the Fire Department annually." The code cited is FFPC 8th Edition, NFPA 101: 39.7.1. The comply-by date is typically 30 days from the inspection date. The status reads Pending Correction.
This violation is one of the most common findings in Broward County commercial and multifamily occupancy inspections, and it is also one of the most correctable. It does not require a licensed contractor to fix a physical system. It requires a written plan, submitted to the local Authority Having Jurisdiction for review, specific enough to tell every person in your building what to do when the fire alarm sounds. The problem is that most building owners and property managers who receive this violation have never written one, do not know what it must contain, and do not know the submission process.
This post explains what the Emergency Action Plan requirement actually demands under NFPA 101 and the Florida Fire Prevention Code, whatyour EAP must include to satisfy your Broward AHJ, how to submit it, and what happens if you miss the comply-by deadline. If you want help building the plan or understanding what your building's fire protection systems require, Speedy Fire Protection's training and consulting team workswith Broward County building owners and managers through exactly this process.
What NFPA 101 Section 39.7.1 Actually Requires
NFPA 101: Life Safety Code Chapter 39 governs existing business occupancies. Section 39.7 covers Operating Features, and Section 39.7.1 is the provision Broward inspection reports cite for the Emergency Action Plan requirement. Whether it applies to your specific building depends on your occupancy classification, which the AHJ determines, and the requirement is enforced under the Florida Fire Prevention Code, 8th Edition, which adopts NFPA 101 as the applicable life safety standard. Enforcement authority in Broward falls to the local AHJ, which varies by municipality. In unincorporated areas and cities served by BSO, the BSO Fire Prevention Bureau is the AHJ. In municipalities with their own fire departments, such as the City of Fort Lauderdale, enforcement is carried out by that city's Fire Marshal.
The core requirement, as stated in the violation language itself, is a written Emergency Action Plan that has been reviewed by the Fire Department, with that review occurring annually. A plan that was written three years ago and filed in a drawer does not satisfy this requirement. A plan that was never submitted to the AHJ does not satisfy this requirement. A plan that exists but has not been updated to reflect changes in the building's layout, tenancy, or emergency contact personnel does not satisfy this requirement.
NFPA 101 Chapter 4.8 establishes the general framework for Emergency Action Plans across all occupancy types. The plan must address how occupants will be notified of an emergency, how they will evacuate or relocate, who is responsible for implementation, and what procedures apply to occupants who may need assistance evacuating. Chapter 39.7.1 applies that framework specifically to existing business occupancies, making it a mandatory operating feature rather than a recommended practice.
The Broward County Local Amendments to the Florida Fire Prevention Code confirm that the FFPC applies countywide, in both incorporated and unincorporated areas. The local amendments do not reduce or eliminate the EAP requirement. They reinforce that fire and life safety inspections for commercial and multifamily occupancies are conducted at least annually, and that violations must be corrected within the time frame stated on the inspection report. To determine your specific submission process, contact the Fire Prevention Bureau or Fire Marshal's office for the city or district where your building is located. For BSO-served areas, contact the BSO Fire Prevention Bureau through sheriff.org for the current submission process.
What Your Emergency Action Plan Must Contain
An Emergency Action Plan is not a generic evacuation map you download from the internet and put your building name on. Your AHJ expects a document that is specific to your building, your occupancy type, and your actual emergency contacts. A generic plan submitted without building-specific content will not satisfy the correction requirement.
The following elements are required under NFPA 101 and the Florida Fire Prevention Code and represent the standard components an AHJ evaluates during EAP review.
Procedure for reporting emergencies. The plan must state how occupants and staff report a fire or other emergency. This includes the procedure for calling 911, how to activate the building fire alarm if it is not already activated, and any internal notification protocols such as contacting a building security desk or property manager. The plan should identify who bears primary responsibility for calling the fire department and what information to provide on that call.
Life safety strategy and evacuation procedures. This is the core of the plan. It must describe how occupants will be notified, how they will exit the building, which exits serve which areas or floors, where the primary and secondary assembly areas are located outside the building, and under what circumstances occupants should shelter in place rather than evacuate. For multi-story commercial buildings, the plan must address floor-by-floor evacuation procedures and the sequence in which floors are evacuated. For buildings with multiple tenants, the plan must account for the fact that different areas may require different evacuation routes.
Procedures for occupants who need evacuation assistance.NFPA 101 requires that the plan specifically address how to assist occupants who may be unable to self-evacuate. This includes persons with mobility limitations, visitors who are unfamiliar with the building, and any occupants in areas with limited egress options. The plan must identify areas of refuge where these occupants can wait for assistance from emergency responders, and assign staff responsibility for checking those areas.
Identification of key personnel and their responsibilities. The plan must name or identify by position the personnel responsible for implementing the plan. This includes the person responsible for conducting a headcount at the assembly area, the person responsible for sweeping floors or areas to confirm evacuation, the person responsible for meeting the fire department at the building entrance and providing information about occupant locations, and the person responsible for verifying the building fire alarm system is functioning. These responsibilities must be assigned before an emergency occurs, not improvised during one.
Major fire hazards associated with normal occupancy. The plan must identify any significant fire hazards present in the building as part of its normal operations. For a commercial warehouse, this includes storage materials, racking heights, and flammable inventory. For a business office, this typically means electrical equipment, document storage, and any kitchen or break room appliances.
Identification of personnel responsible for fire protection system maintenance. The plan must state who is responsible for ensuring the building's fire protection systems, including fire sprinklers, alarms, and extinguishers, are properly maintained. This does not mean the building owner personally maintains them. It means the plan names the responsible party and, where applicable, the licensed contractor engaged to perform that work.
Recall and re-entry procedures. The plan must address how the all-clear signal is communicated to occupants waiting at the assembly area and who has authority to authorize re-entry into the building after an emergency.
The Annual Review Requirement and Why It Gets Buildings Into Trouble
The violation language says "reviewed by the Fire Department annually." That word annually is where most buildings fall short. A property that had an EAP approved three years ago, when it was under different management with different tenants in different spaces, is not compliant. The plan must be current, and it must be re-submitted to the AHJ for review each year.
Buildings that change ownership, change property management companies, renovate interior spaces, or add or lose tenants frequently allow the EAP to go stale because no one in the transition explicitly took ownership of the annual review obligation. The outgoing manager knows it was done two years ago. The incoming manager assumes it was recently updated. Neither verifies. The next annual fire inspection surfaces the gap, and the building receives the violation.
Broward County's fire inspection framework is enforced under the Florida Fire Prevention Code, 8th Edition, with inspections conducted at least annually for commercial and multifamily occupancies. The BSO Fire Prevention Bureau conducts these inspections for BSO-served municipalities. City fire departments handle inspections in their respective jurisdictions. Buildings that submit their EAP annually, conduct drills, and document everything are rarely cited for this violation.
What Happens If You Miss the Comply-By Deadline
The Notice of Violation issued by your Broward AHJ sets a comply-by date, typically 30 days from the inspection date. If the correction is not made by that date, enforcement escalates.
Under the Broward County Local Amendments to the Florida Fire Prevention Code, any person or entity that violates a provision of the FFPC or fails to comply with any of its requirements is guilty of a misdemeanor. Each day a violation continues constitutes a separate offense. Upon conviction, the violation is punishable by a fine of not less than $50 and not more than $500 per day, or by imprisonment not exceeding 60 days, or both.
The EAP violation is also worth addressing promptly because it often appears alongside other violations on the same inspection report, such as missing annual fire sprinkler inspection reports, absent fire alarm documentation, or other fire protection deficiencies. Each violation has its own comply-by deadline. Addressing all of them in parallel, rather than one at a time, is the most efficient path to clearing the inspection record.
How to Correct the Violation and Submit Your EAP
The correction path for an EAP violation in Broward County depends on which AHJ issued the violation. The inspection report will identify the issuing authority. For properties in BSO-served areas, contact the BSO Fire Prevention Bureau through sheriff.org to confirm the EAP submission process and any required forms. For properties in cities with their own fire departments, contact that city's Fire Marshal or Fire Prevention Bureau directly to obtain the submission instructions for your jurisdiction.
Before submitting, confirm your plan includes all of the elements described above. A plan that is missing key personnel assignments, does not address occupants who need evacuation assistance, or omits a major fire hazard present in the building will not pass review and will require resubmission. Each resubmission costs time against your comply-by deadline.
After submission, retain confirmation of the submission and any approval documentation from the AHJ. That documentation is what you present during the follow-up inspection to confirm the violation has been corrected. Keep it on file for the full year until the next annual review cycle.
For buildings with multiple violations on the same report, address fire protection system violations concurrently. If you also received a violation for failing to provide a current annual fire sprinkler inspection and testing report, that requires a licensed fire sprinkler contractor to perform and document the inspection. Our inspection and testing team can schedule and complete that work on the timeline your comply-by date requires, and produce the NFPA 25-compliant report the AHJ expects to see.
Speedy Fire Protection: Consulting and Compliance Support for Broward County Buildings
Speedy Fire Protection has served Miami-Dade, Broward, and Palm Beach for more than 20 years as a Florida Licensed Fire Sprinkler Contractor (#FPC25-000020).
We understand both the technical and procedural requirements of fire code enforcement across Broward County's multiple AHJs, and we work directly with building owners and property managers to resolve violations efficiently.
Our training and consulting practice works directly with building owners, property managers, and condo associations facing fire code violations. We help clients understand what each violation requires, build a correction plan that addresses all open items efficiently, and establish the annual compliance calendar that prevents the same violations from recurring. For EAP violations specifically, we can advise on plan content, review your draft against AHJ expectations before submission, and help you build the annual review process into your property management workflow. Raul J. Muniz, Esq., a Florida-licensed attorney and partner at Speedy, is available to advise on the legal and compliance dimensions of fire code enforcement for property owners with complex situations.
If your building has also received violations related to fire sprinkler systems or missing inspection reports, our inspection and testing and service and repair teams can address those on the same timeline. We coordinate across all the fire protection work so that you are not managing multiple contractors against the same deadline.
Contact Speedy Fire Protection as soon as you receive a Notice of Violation. The 30-day window moves fast, and the most common mistake is waiting until the final week to start assembling the required documentation.
Frequently Asked Questions
Q: What is an Emergency Action Plan and why is it required in Broward County?
An Emergency Action Plan is a written document that tells every occupant and staff member in a building what to do when an emergency occurs, specifically including how to evacuate, who is responsible for implementing the plan, and how to assist occupants who need help. NFPA 101 Section 39.7.1 requires existing business occupancies to have an EAP that has been reviewed by the Fire Department. In Broward County, that requirement is enforced under the Florida Fire Prevention Code, 8th Edition, by the applicable local AHJ during annual fire safety inspections. Whether it applies to your specific building depends on your occupancy classification, which your AHJ determines; the inspection report itself identifies the code section being enforced.
Q: How do I submit my Emergency Action Plan to my Broward County AHJ for review?
The submission process varies by jurisdiction within Broward County. The violation notice from your inspection authority will identify the issuing agency. For BSO-served areas, contact the BSO Fire Prevention Bureau through sheriff.org to confirm the current submission process, which may include an online portal, email submission, or in-person delivery. For municipalities with their own fire departments, such as Fort Lauderdale, Hollywood, or Pembroke Pines, contact that city's Fire Prevention Bureau directly. Always retain confirmation of your submission and any approval documentation for your records.
Q: What happens if I miss the comply-by date on the violation?
Failure to correct a violation by the comply-by date can result in escalating enforcement action. Under the Broward County Local Amendments to the Florida Fire Prevention Code, violations carry fines of $50 to $500 per day, with each additional day of non-compliance constituting a separate offense. Enforcement can escalate further the longer the violation remains open. If you are unable to correct the violation by the comply-by date, contact the issuing authority promptly to communicate your status and ask about any extension process. Do not simply allow the deadline to pass without communication.
Q: How often does the Emergency Action Plan need to be reviewed?
NFPA 101 as enforced through the Florida Fire Prevention Code and reflected in the violation language, the EAP must be reviewed by the Fire Department annually. That means each year you must re-submit an updated plan to the AHJ and obtain approval. A plan approved in a prior year that has not been re-submitted for the current year does not satisfy the requirement. Build the annual EAP review into your property management calendar at the same time as your annual fire sprinkler inspection and fire alarm testing. Treating all three as part of the same annual compliance cycle is the most reliable way to avoid recurring violations.
Q: My building received other violations on the same report alongside the EAP violation. Do I need to address all of them by the same deadline?
Each violation on the Broward inspection report carries its own comply-by date, which is typically the same date for all violations on a single report. All violations must be corrected and documented before the follow-up inspection. For violations that require a licensed fire sprinkler contractor, such as a missing annual sprinkler inspection and testing report, you will need to engage a Florida Licensed Fire Sprinkler Contractor to perform and document that work. Addressing all violations in parallel rather than sequentially is the most efficient approach given the shared deadline.
Speedy Fire Protection is a Florida Licensed Fire Sprinkler Contractor (#FPC25-000020) serving Miami-Dade, Broward, Palm Beach, and surrounding South Florida counties. This article is for informational purposes only and does not constitute legal advice. Consult a licensed fire protection contractor and qualified legal counsel for guidance specific to your property.